Industrial differential pressure gauge -welded

For gas and liquid media which are not adhesive or crystallizable, as well as for work in an aggressive environment. Max. temperature of the measured media 100°C and 200°C

Application:

Pump monitoring and controlling. Filter monitoring. Level measurement in closed containers.

 

 

 

 

 

 

 

 

 

Factor

Standard

Nominal diameter

100, 160 mm

Accuracy class

1,6

Ranges

0 ... 160 mbar; 0 ... 25 bar

Ambient temperature

-20 ... 60°C

Temperature error

Additional temperature error when the temperature value of the measured element abberates from +20 °C

±0,5%/10K of actual range of indication

Display unit’s case

Acid proof steel

Dial

Aluminium, painted white

Pane

Laminated Glass, safe

Connector pipe

Acid proof steel

Mechanism

Acid proof steel

Type of connector pipe

Radial

Connector pipe’s thread

2 x G 1/4

Optional

Different connector’s thread
Glycerine filling